| Standard Packaging: | Wooden Case |
| Payment Method: | T/T |
Our High Performance Water to Water Liquid Cooling Unit is engineered to provide reliable thermal management for IGBT power modules, power conversion equipment, and energy storage systems. It is designed for industrial applications where stable cooling performance, efficient heat transfer, and continuous equipment operation are essential.
The cooling unit adopts a water to water heat exchange structure, transferring heat from the primary equipment cooling circuit to a secondary water circuit through a high-efficiency heat exchanger. This configuration allows independent circulation loops and helps maintain appropriate operating temperatures for connected electrical equipment.
The integrated system can include plate heat exchangers, circulation pumps, control valves, pipelines, temperature sensors, pressure instruments, and intelligent control components. Its hydraulic design supports coordinated coolant circulation and flexible connection with different industrial cooling infrastructures.
Our Water to Water Liquid Cooling Unit can be customized according to cooling capacity, water flow rate, inlet and outlet temperatures, operating pressure, and installation requirements. It provides a practical cooling solution for IGBT power conversion, battery energy storage, renewable energy equipment, and industrial power electronics.
![]()
Efficient heat exchange between primary and secondary water circuits
High-performance heat exchanger configuration
Independent cooling loop design for flexible system integration
Optimized hydraulic circulation and water distribution
Stable heat transfer for high-power electrical equipment
Customized cooling capacity for different thermal loads
Suitable for compatible high-power IGBT modules
Supports industrial power converters and inverter systems
Applicable to power electronic control equipment
Helps maintain suitable operating temperatures
Designed for demanding industrial cooling applications
Flexible integration with existing cooling infrastructure
Real-time coolant temperature monitoring options
Water flow and pressure monitoring
Circulation pump operating status monitoring
Automatic temperature control options
Configurable alarm and fault protection functions
PLC-based intelligent control system
Optional HMI touchscreen interface
Remote communication and centralized monitoring support
Available monitoring functions and communication interfaces depend on the selected control configuration.
Stable coolant circulation through optimized hydraulic design
Heat exchanger selection based on actual thermal requirements
Configurable operating parameters for different applications
Integrated circulation components for convenient installation
Optional filtration and water quality management
Maintenance-friendly system arrangement
Flexible engineering configurations for industrial projects
![]()
Designed for compatible IGBT power modules used in high-power conversion equipment. The cooling unit helps remove heat generated during operation and supports stable thermal management.
Suitable for compatible power conversion equipment in battery energy storage installations, including PCS systems and associated electrical equipment requiring dedicated liquid cooling.
Applicable to industrial inverter systems, variable frequency drives, and power conversion equipment requiring efficient heat exchange and controlled coolant circulation.
Supports selected solar power conversion equipment, wind power electrical systems, and renewable energy installations where reliable liquid cooling is required.
Suitable for compatible rectifiers, SVG systems, UPS equipment, industrial power supplies, and other high-power electronic applications.
Can be integrated into industrial cooling infrastructure where separate primary and secondary water circulation circuits are required for equipment heat removal.
The water to water heat exchange structure transfers thermal energy between two independent water circuits. Proper heat exchanger sizing helps meet the cooling requirements of high-power electrical equipment.
The integrated hydraulic design supports coordinated water circulation through pumps, pipelines, valves, and heat exchangers. Optional monitoring and protection functions help operators manage system conditions.
Optimized hydraulic layouts, suitable pump selection, and heat exchanger design can help improve overall cooling system efficiency under specified operating conditions.
Optional filtration and water treatment components help maintain suitable coolant conditions, reduce contamination risks, and support long-term system maintenance.
The cooling unit can be configured with different connection interfaces, piping arrangements, control functions, and installation dimensions to meet project-specific requirements.
Cooling capacity, heat exchanger type, circulation components, and control configurations can be selected according to equipment specifications and actual operating conditions.
| Item | Specification |
|---|---|
| Product Name | High Performance Water to Water Liquid Cooling Unit |
| Product Type | Industrial Liquid Cooling Equipment |
| Cooling Method | Water to Water Heat Exchange |
| Main Application | IGBT Power Conversion and Energy Storage Systems |
| Heat Exchanger | Plate Heat Exchanger or Customized Type |
| Primary Cooling Circuit | Equipment Cooling Water Loop |
| Secondary Cooling Circuit | External Heat Rejection Water Loop |
| Cooling Medium | Water or Specified Compatible Coolant |
| Circulation System | Integrated Pump and Piping Configuration |
| Hydraulic Design | Optimized Water Flow Distribution |
| Control System | PLC-Based Intelligent Control Optional |
| HMI Interface | Optional Touchscreen Display |
| Monitoring Functions | Temperature, Pressure, Flow, and Fault Monitoring |
| Communication | Optional Remote Communication Interface |
| Cooling Capacity | Customized According to Thermal Load |
| Installation Type | Integrated Skid or Customized Configuration |
| Applications | IGBT, PCS, Inverters, Energy Storage, Power Electronics |
Final specifications, including cooling capacity, flow rate, operating pressure, water inlet and outlet temperatures, dimensions, and electrical requirements, should be confirmed according to the actual equipment model and project conditions.
The High Performance Water to Water Liquid Cooling Unit supports various optional configurations to accommodate different industrial cooling requirements.
Customized plate heat exchanger capacity and selection
Integrated circulation pumps and hydraulic assemblies
Temperature, pressure, and flow monitoring sensors
Automatic electrical control cabinet
PLC intelligent control and HMI touchscreen interface
Water filtration and treatment components
Customized stainless steel or other specified piping materials
Automatic alarm and equipment protection functions
Optional pump redundancy and backup configurations
Remote monitoring and industrial communication interfaces
Customized skid dimensions and installation arrangements
Project-specific inlet and outlet connection interfaces
The final configuration can be selected according to cooling requirements, equipment compatibility, operating environment, and project specifications.
Our High Performance Water to Water Liquid Cooling Unit combines efficient heat exchange technology, integrated hydraulic circulation, and flexible control configurations to provide reliable thermal management for industrial power conversion and energy storage applications.
The system is designed to support stable coolant circulation and effective heat removal from compatible IGBT modules, power converters, and related electrical equipment. Its independent water circuit configuration allows flexible integration with different external cooling systems.
With customizable heat exchanger selection, circulation pump arrangements, monitoring functions, and installation layouts, the cooling unit can be adapted to different industrial project requirements.
We focus on practical engineering design, component compatibility, and customized system configuration to help customers select suitable liquid cooling solutions for their applications.
We provide project-oriented engineering support for industrial water to water cooling applications, including:
Cooling capacity assessment and system configuration
Heat exchanger selection and technical evaluation
Primary and secondary water circuit design coordination
Circulation pump and piping system configuration
Temperature, pressure, and flow monitoring solutions
PLC control and electrical cabinet customization
Installation dimensions and equipment layout planning
Technical specification confirmation and project coordination
To recommend a suitable cooling unit, customers can provide the required cooling capacity, equipment heat load, inlet and outlet water temperatures, water flow rate, operating pressure, and installation conditions.
Looking for a high-performance Water to Water Liquid Cooling Unit for IGBT power conversion or energy storage systems?
Our engineering team can assist with cooling system selection, technical configuration, and customized equipment solutions based on your application requirements.
Contact us today to discuss your project and receive product specifications, technical support, and a customized quotation.