Products
PRODUCTS DETAILS
Home > Products >
High Performance Water to Water Liquid Cooling Unit for IGBT Power Conversion and Energy Storage Systems

High Performance Water to Water Liquid Cooling Unit for IGBT Power Conversion and Energy Storage Systems

Standard Packaging: Wooden Case
Payment Method: T/T
Detail Information
Place of Origin
China
Brand Name
YUDA
Certification
CE ISO9001
Applicable Industries:
Manufacturing Plant, Industry Melting
Ambient Temperature Range:
Minus 20 To 45 Degrees Celsius
Energy Efficiency:
High-efficiency Heat Exchange Design
Communication Interface:
RS485 Ethernet Optional
Compatibility:
Intel And AMD Sockets
Test Pressure:
Up To 1.5 Times Working Pressure
Length:
10 Meters
Installation Type:
Tool-free Mounting
Liquid Flow Rate:
150–220 L/min
Wall Thickness Tolerance:
±0.05 Mm
Installation Method:
Rail Mounted Or Frame Mounted
Joint Sealing Performance:
High Temperature Leak Proof
Product Description

High Performance Water to Water Liquid Cooling Unit for IGBT Power Conversion and Energy Storage Systems

Product Description

Our High Performance Water to Water Liquid Cooling Unit is engineered to provide reliable thermal management for IGBT power modules, power conversion equipment, and energy storage systems. It is designed for industrial applications where stable cooling performance, efficient heat transfer, and continuous equipment operation are essential.

The cooling unit adopts a water to water heat exchange structure, transferring heat from the primary equipment cooling circuit to a secondary water circuit through a high-efficiency heat exchanger. This configuration allows independent circulation loops and helps maintain appropriate operating temperatures for connected electrical equipment.

The integrated system can include plate heat exchangers, circulation pumps, control valves, pipelines, temperature sensors, pressure instruments, and intelligent control components. Its hydraulic design supports coordinated coolant circulation and flexible connection with different industrial cooling infrastructures.

Our Water to Water Liquid Cooling Unit can be customized according to cooling capacity, water flow rate, inlet and outlet temperatures, operating pressure, and installation requirements. It provides a practical cooling solution for IGBT power conversion, battery energy storage, renewable energy equipment, and industrial power electronics.

High Performance Water to Water Liquid Cooling Unit for IGBT Power Conversion and Energy Storage Systems

Key Features

High Performance Water to Water Cooling Technology

  • Efficient heat exchange between primary and secondary water circuits

  • High-performance heat exchanger configuration

  • Independent cooling loop design for flexible system integration

  • Optimized hydraulic circulation and water distribution

  • Stable heat transfer for high-power electrical equipment

  • Customized cooling capacity for different thermal loads

Designed for IGBT and Power Conversion Applications

  • Suitable for compatible high-power IGBT modules

  • Supports industrial power converters and inverter systems

  • Applicable to power electronic control equipment

  • Helps maintain suitable operating temperatures

  • Designed for demanding industrial cooling applications

  • Flexible integration with existing cooling infrastructure

Intelligent Control and Monitoring

  • Real-time coolant temperature monitoring options

  • Water flow and pressure monitoring

  • Circulation pump operating status monitoring

  • Automatic temperature control options

  • Configurable alarm and fault protection functions

  • PLC-based intelligent control system

  • Optional HMI touchscreen interface

  • Remote communication and centralized monitoring support

Available monitoring functions and communication interfaces depend on the selected control configuration.

Reliable Cooling Performance

  • Stable coolant circulation through optimized hydraulic design

  • Heat exchanger selection based on actual thermal requirements

  • Configurable operating parameters for different applications

  • Integrated circulation components for convenient installation

  • Optional filtration and water quality management

  • Maintenance-friendly system arrangement

  • Flexible engineering configurations for industrial projects

High Performance Water to Water Liquid Cooling Unit for IGBT Power Conversion and Energy Storage Systems

Typical Applications

IGBT Power Conversion Systems

Designed for compatible IGBT power modules used in high-power conversion equipment. The cooling unit helps remove heat generated during operation and supports stable thermal management.

Battery Energy Storage Systems

Suitable for compatible power conversion equipment in battery energy storage installations, including PCS systems and associated electrical equipment requiring dedicated liquid cooling.

Industrial Inverter Cooling

Applicable to industrial inverter systems, variable frequency drives, and power conversion equipment requiring efficient heat exchange and controlled coolant circulation.

Renewable Energy Systems

Supports selected solar power conversion equipment, wind power electrical systems, and renewable energy installations where reliable liquid cooling is required.

High Power Electrical Equipment

Suitable for compatible rectifiers, SVG systems, UPS equipment, industrial power supplies, and other high-power electronic applications.

Industrial Thermal Management

Can be integrated into industrial cooling infrastructure where separate primary and secondary water circulation circuits are required for equipment heat removal.

Product Advantages

Efficient Heat Transfer Performance

The water to water heat exchange structure transfers thermal energy between two independent water circuits. Proper heat exchanger sizing helps meet the cooling requirements of high-power electrical equipment.

Stable Cooling System Operation

The integrated hydraulic design supports coordinated water circulation through pumps, pipelines, valves, and heat exchangers. Optional monitoring and protection functions help operators manage system conditions.

Energy Efficient Configuration

Optimized hydraulic layouts, suitable pump selection, and heat exchanger design can help improve overall cooling system efficiency under specified operating conditions.

Advanced Water Quality Management

Optional filtration and water treatment components help maintain suitable coolant conditions, reduce contamination risks, and support long-term system maintenance.

Flexible Industrial Integration

The cooling unit can be configured with different connection interfaces, piping arrangements, control functions, and installation dimensions to meet project-specific requirements.

Customized Engineering Solutions

Cooling capacity, heat exchanger type, circulation components, and control configurations can be selected according to equipment specifications and actual operating conditions.

Technical Specifications

Item Specification
Product Name High Performance Water to Water Liquid Cooling Unit
Product Type Industrial Liquid Cooling Equipment
Cooling Method Water to Water Heat Exchange
Main Application IGBT Power Conversion and Energy Storage Systems
Heat Exchanger Plate Heat Exchanger or Customized Type
Primary Cooling Circuit Equipment Cooling Water Loop
Secondary Cooling Circuit External Heat Rejection Water Loop
Cooling Medium Water or Specified Compatible Coolant
Circulation System Integrated Pump and Piping Configuration
Hydraulic Design Optimized Water Flow Distribution
Control System PLC-Based Intelligent Control Optional
HMI Interface Optional Touchscreen Display
Monitoring Functions Temperature, Pressure, Flow, and Fault Monitoring
Communication Optional Remote Communication Interface
Cooling Capacity Customized According to Thermal Load
Installation Type Integrated Skid or Customized Configuration
Applications IGBT, PCS, Inverters, Energy Storage, Power Electronics

Final specifications, including cooling capacity, flow rate, operating pressure, water inlet and outlet temperatures, dimensions, and electrical requirements, should be confirmed according to the actual equipment model and project conditions.

Optional Configurations

The High Performance Water to Water Liquid Cooling Unit supports various optional configurations to accommodate different industrial cooling requirements.

  • Customized plate heat exchanger capacity and selection

  • Integrated circulation pumps and hydraulic assemblies

  • Temperature, pressure, and flow monitoring sensors

  • Automatic electrical control cabinet

  • PLC intelligent control and HMI touchscreen interface

  • Water filtration and treatment components

  • Customized stainless steel or other specified piping materials

  • Automatic alarm and equipment protection functions

  • Optional pump redundancy and backup configurations

  • Remote monitoring and industrial communication interfaces

  • Customized skid dimensions and installation arrangements

  • Project-specific inlet and outlet connection interfaces

The final configuration can be selected according to cooling requirements, equipment compatibility, operating environment, and project specifications.

Why Choose Our High Performance Water to Water Liquid Cooling Unit?

Our High Performance Water to Water Liquid Cooling Unit combines efficient heat exchange technology, integrated hydraulic circulation, and flexible control configurations to provide reliable thermal management for industrial power conversion and energy storage applications.

The system is designed to support stable coolant circulation and effective heat removal from compatible IGBT modules, power converters, and related electrical equipment. Its independent water circuit configuration allows flexible integration with different external cooling systems.

With customizable heat exchanger selection, circulation pump arrangements, monitoring functions, and installation layouts, the cooling unit can be adapted to different industrial project requirements.

We focus on practical engineering design, component compatibility, and customized system configuration to help customers select suitable liquid cooling solutions for their applications.

Custom Design and Engineering Support

We provide project-oriented engineering support for industrial water to water cooling applications, including:

  • Cooling capacity assessment and system configuration

  • Heat exchanger selection and technical evaluation

  • Primary and secondary water circuit design coordination

  • Circulation pump and piping system configuration

  • Temperature, pressure, and flow monitoring solutions

  • PLC control and electrical cabinet customization

  • Installation dimensions and equipment layout planning

  • Technical specification confirmation and project coordination

To recommend a suitable cooling unit, customers can provide the required cooling capacity, equipment heat load, inlet and outlet water temperatures, water flow rate, operating pressure, and installation conditions.

Request a Quote

Looking for a high-performance Water to Water Liquid Cooling Unit for IGBT power conversion or energy storage systems?

Our engineering team can assist with cooling system selection, technical configuration, and customized equipment solutions based on your application requirements.

Contact us today to discuss your project and receive product specifications, technical support, and a customized quotation.