Detail Information
Place of Origin
China
Brand Name
YUDA
Certification
CE ISO9001
Joint Sealing Performance:
High Temperature Leak Proof
Pressure Drop:
Less Than 0.15 MPa
Mechanical Strength:
350–450 MPa Tensile Strength
Appalication:
For Induction Furnace
Temperature Control:
Automatic Regulation With High Accuracy
Manufacturing Standard:
EN And ISO Railway Industry Standards
Application Field:
Industrial And Railway Cooling Systems
Coolingmethod:
Air Cooling / Liquid Cooling
Pump Type:
Ceramic Bearing Pump
Key Selling Points:
Easy To Operate
Fan Speed:
800-2000 RPM
Connectiontype:
Threaded
Highlight:

Water to Water Cooling Unit for IGBT

,

Liquid Cooling Unit for Power Electronics

,

High Voltage Water Cooling System

Product Description

High Efficiency Water to Water Liquid Cooling Unit for High Voltage IGBT and Power Electronic Systems

Product Description

Our High Efficiency Water to Water Liquid Cooling Unit is designed to provide reliable heat removal and stable temperature management for high voltage IGBT modules, power converters, and other high-power electronic equipment. It is suitable for industrial power electronics, renewable energy systems, energy storage installations, and applications requiring efficient liquid cooling.

The water to water cooling system transfers heat from the primary cooling circuit to a secondary water circuit through a heat exchanger. This configuration helps separate the equipment cooling loop from the external heat rejection circuit, supporting stable thermal management and flexible system integration.

With an integrated hydraulic circulation design, the unit can incorporate pumps, heat exchangers, piping, valves, sensors, and control components according to project requirements. The system can be configured to support continuous operation, temperature monitoring, and coordinated cooling control for demanding industrial applications.

Our High Efficiency Water to Water Liquid Cooling Unit can be customized according to cooling capacity, inlet and outlet water temperatures, operating pressure, flow rate, and installation conditions. It provides a practical cooling solution for high voltage IGBT equipment and power electronic systems that require dependable heat dissipation.

High Efficiency Water to Water Liquid Cooling Unit for High Voltage IGBT and Power Electronic Systems

Key Features

High Efficiency Water to Water Cooling Technology

  • Heat exchange between primary and secondary water circuits

  • Efficient heat transfer for high-power electronic equipment

  • Independent cooling circuit configuration

  • Integrated piping and hydraulic circulation components

  • Flexible design for different cooling requirements

  • Compact system integration options

Designed for IGBT and Power Electronics Cooling

  • Suitable for compatible high voltage IGBT modules

  • Supports cooling for power converters and inverter systems

  • Applicable to industrial power conversion equipment

  • Helps maintain stable operating temperatures when correctly sized

  • Configurable for continuous-duty industrial applications

  • Supports integration into customized thermal management systems

Intelligent Control and Monitoring

  • Temperature monitoring options for cooling circuits

  • Flow monitoring and pressure measurement options

  • Pump operation control and system status monitoring

  • Alarm functions for selected operating conditions

  • Optional communication interfaces for system integration

  • Customized control logic according to project requirements

Available monitoring functions and communication protocols depend on the selected control configuration.

Reliable Cooling Performance

  • Stable coolant circulation through properly designed hydraulic circuits

  • Heat exchanger selection based on required thermal load

  • Configurable operating parameters for different applications

  • Integrated components for simplified system installation

  • Maintenance access designed around project requirements

  • Support for customized cooling system configurations

Typical Applications

High Voltage IGBT Cooling

Designed for compatible high voltage IGBT modules used in power conversion, industrial electrical equipment, and high-power control systems. The cooling unit helps remove heat generated during equipment operation.

Power Converter and Inverter Cooling

Suitable for compatible converters and inverter systems used in industrial power conversion, renewable energy equipment, and electrical infrastructure.

Energy Storage Systems

Can be integrated into suitable energy storage power conversion and thermal management systems where water to water heat exchange is required.

Renewable Energy Equipment

Applicable to selected solar power conversion equipment, wind power electrical systems, and other renewable energy applications requiring controlled liquid cooling.

Industrial Power Electronics

Suitable for industrial rectifiers, power supplies, electrical control equipment, and other compatible high-power electronic systems.

Specialized Industrial Cooling

Can be configured for customized industrial thermal management projects that require heat transfer between two water circuits.

High Efficiency Water to Water Liquid Cooling Unit for High Voltage IGBT and Power Electronic Systems

Product Advantages

Efficient Heat Transfer

The water to water configuration uses a heat exchanger to transfer heat between separate cooling circuits. Proper heat exchanger sizing helps meet the thermal load of the connected equipment and supports efficient heat removal.

Stable System Operation

The integrated cooling configuration can include circulation pumps, monitoring instruments, control valves, and protective functions to support stable operation under specified working conditions.

Energy Efficient Design

Pump selection, hydraulic resistance, heat exchanger performance, and control strategy can be optimized according to actual operating requirements to help reduce unnecessary energy consumption.

Advanced Water Quality Management

The primary and secondary cooling circuits can be configured according to equipment requirements and water quality conditions. Appropriate filtration, water treatment, and corrosion protection measures can help support long-term system reliability.

Flexible System Integration

The cooling unit can be adapted to different equipment layouts, piping interfaces, control requirements, and installation environments. Customized configurations help simplify integration into existing or newly developed systems.

Technical Specifications

Item Specification
Product Name High Efficiency Water to Water Liquid Cooling Unit
Product Type Water to Water Liquid Cooling System
Primary Application High Voltage IGBT and Power Electronics Cooling
Cooling Method Water to Water Heat Exchange
Heat Exchanger Plate Heat Exchanger or Customized Type
Circulation System Integrated or Customized Pump and Piping Configuration
Cooling Medium Water or Specified Compatible Coolant
Temperature Control Optional Automatic Temperature Monitoring and Control
Flow Monitoring Optional Flow and Pressure Monitoring
Control System Customized Electrical Control System
Communication Optional Industrial Communication Interfaces
Installation Type Integrated Skid or Customized Industrial Unit
Cooling Capacity Selected According to Project Requirements
Operating Pressure Confirmed According to System Design
Flow Rate Configured According to Thermal Load
Inlet and Outlet Temperature Customized According to Application
Application Areas IGBT Equipment, Power Converters, Energy Storage, Renewable Energy, Industrial Power Electronics

Final specifications should be confirmed according to the actual cooling load, water quality, operating temperature, pressure requirements, and selected system configuration.

Optional Configurations

The High Efficiency Water to Water Liquid Cooling Unit can be supplied with selected optional features according to project requirements.

  • Customized heat exchanger capacity and configuration

  • Integrated circulation pumps and piping assemblies

  • Temperature, pressure, and flow sensors

  • Automatic control cabinet and monitoring functions

  • Filtration and water treatment components

  • Customized piping materials and connection interfaces

  • Optional alarm and equipment protection functions

  • Remote monitoring or communication interfaces

  • Customized skid dimensions and installation arrangements

The availability of each option depends on the technical design and project specifications.

Why Choose Our High Efficiency Water to Water Liquid Cooling Unit

Our water to water liquid cooling units are designed around the thermal management requirements of high-power electronic equipment. By combining heat exchange technology, hydraulic circulation components, and configurable control functions, the system can provide a coordinated cooling solution for compatible IGBT and power electronic applications.

We support project-based configuration to help customers select suitable heat exchanger capacity, circulation flow, operating pressure, temperature monitoring, and control functions. This approach helps align the cooling unit with the equipment's actual thermal load and installation conditions.

Whether used in industrial power conversion, renewable energy equipment, or energy storage applications, the system can be configured to meet specific cooling and integration requirements.

Custom Design and Engineering Support

We provide technical coordination for customers seeking customized water to water liquid cooling equipment.

Our support may include:

  • Cooling capacity assessment

  • Heat exchanger selection and configuration

  • Primary and secondary circuit design coordination

  • Pump and piping configuration

  • Temperature and flow monitoring options

  • Electrical control and communication requirements

  • Installation interface and equipment layout planning

  • Technical specification confirmation and quotation

To support accurate selection, customers are encouraged to provide the required cooling capacity, inlet and outlet water temperatures, flow rate, operating pressure, coolant type, and installation conditions.

Request a Quote

Looking for a reliable High Efficiency Water to Water Liquid Cooling Unit for high voltage IGBT or power electronic equipment?

Contact our team with your application details and cooling requirements. We can help evaluate a suitable system configuration and provide product information, technical support, and a customized quotation based on your project specifications.